HYDOR - Koralia Nano Water Pump - 425 Gph

Product Description
$51.49 CAD
KORALIA NANO is a new innovative pump for water movement in mini and nano-reef aquariums. The exclusive Hydor design and technology guarantee a continuous and powerful water flow which can be directed freely thanks to the special sphere shaped connection to the exclusive patented magnet support.

High performance, low energy consumption, quick and easy maintenance.

Compact, energy saving, this Koralia Pump is ideal to recreate in aquarium the natural and beneficial water motion of rivers and seas. Supplied with patented magnet-suction cup support for easy and safe positioning, Koralia can be connected to a controller and set to intervals of seconds, minutes or hours. Cable protector include (read instructions for correct positioning).

Package Description: 425 Gph

Serving Size: ..

Number of Servings: ..


TYPE

W

FLOWRATE

FOR AQUARIUMS

freshwater marine

115 V - 60 Hz

KORALIA NANO 240

3.5

240 gph

from 16 to 18 gal

from 10 to 15 gal
KORALIA NANO 425
3.5 425 gph from 28 to 50 gal
from 15 to 30 gal

TYPE

USA CODE

KORALIA NANO 240 P29101
KORALIA NANO 425
P29201


Installation
Attention: please verify that all components of the pump are undamaged before putting it into function. Before any kind of intervention, always disconnect electrical supply of the pump and any other appliance placed in the water. Be sure that the voltage of the mains supply corresponds to the voltage shown on the unit’s label. In order to prevent noise and disturbance caused by vibration we suggest to position the pump avoiding lateral contact with the aquarium glass or in an upward position on the bottom.
  • Unwind the electric cable.
  • Insert the cylinder on the sphere attachment to the pump in the proper slot.
  • Immerse the pump completely and turn it in a vertical position in order to allow any air to come out of the impeller chamber.
  • Attach the pump with the internal part of the suction cup and magnet support to the aquarium side. Be sure to clean the surface before attaching the support.
  • Adjust flow direction as desired.
  • Connect to electrical supply.

Maintenance
Note: Before any kind of intervention, always disconnect electrical supply of the pump and any other appliance placed in the water.

  • Regular cleaning and maintenance will guarantee the pump better and longer performance.
  • With one hand, hold the pump assembly. Use your other hand to remove the external magnet.
  • Disassemble the unit.
  • Clean the impeller assembly, the chamber and the bearings removing deposits with a soft brush. Do not use detergents or solvents.
  • If necessary, clean the grid of the lower and upper chamber by putting it under running tap water or using a soft brush to remove algae and other residue.
  • Reassemble everything in reverse order. Make sure that the bearings are positioned correctly, allowing the rotor correct axial movement. Make sure the rotor holder is placed correctly.
  • In case of abnormal noise and reduced performance caused by sudden changes in electricity supply, restart the pump.
Safety information Attention: Please verify that all components of the pump are undamaged before putting it into function. Before any kind of intervention, ALWAYS disconnect electrical supply of the pump and any other appliance placed in the water. Be sure that the voltage of the mains supply corresponds to the voltage shown on the unit’s label. The pump is intended for indoor use only in fl uid with a temperature of max. 35° C (95° F). DO NOT RUN DRY - Do not connect to electrical supply if pump is not completely immersed in water. Do not connect to electrical supply if pump is missing parts. Do not connect to electrical supply if pump is not positioned using the supplied suction-cup + magnet support. The cord of this pump cannot be replaced or repaired; in case of damage the entire unit must be substituted. Do not cut or pull on the electrical cord. Always disconnect from mains gently and make sure hands are dry. When in function, make sure that the pump surface is not blocked. When in function, make sure that the pump does not take in sand, as this could seriously damage the unit and void the guarantee (read carefully the maintenance paragraph). Due to the high attraction level between the magnets in the support, keep out of reach of children. Avoid attaching the magnets directly to one-another. Make sure you hold the magnets from the sides and avoid placing hands or fingers in between. At a distance up to 5 cm (2 inches) the magnets attract metal objects and other magnets with a high force: to prevent injuries, avoid closeness with blades, sharp objects or other magnets. The magnet can cause permanent damage to electrical devices or articles that are affected by a magnetic field such as pacemakers, credit cards, or keys: always maintain them at a minimum distance of 30 cm (12 inches). When not in use, always place the carton separator between magnets. If exposed to temperature higher than 50° C (122° F) the magnets can lose part or all the attracting power. Always clean the aquarium side before placing the suctions cup + magnet support: any dirt on the surface might prevent the suction cup from attaching properly and the pump might slip on the bottom of the aquarium causing damage to things and itself. Please keep these instruction in a safe and dry place.

A collection of authentic customer reviews of Vitamin Grocer collected by Reviews.co.uk, a Google-licensed third-party review platform.